A Level 2 chimney report, no translator needed
Picture page one of the report: the address, the flue size, a photo of the firebox, and a short line that says whether the fireplace drew smoke up or spilled it into the room.
Book the sale inspection
A name and number are enough. When we call, we ask for the address, who can open the house and who the report is for.
Page one: the summary line
The top of the report names the house, the appliance and the flue, then gives one plain sentence on condition. Something like: masonry fireplace, clay tile flue, three cracked tiles in the upper third, smoke rolled out of the opening during the lit test. That sentence is what most agents copy into their notes, so we write it to stand on its own.
Under it sits a short table. Each row is one part of the system, from the hearth to the cap, with a mark for sound, needs attention, or needs repair before use. A buyer can see at a glance whether the trouble is cosmetic or whether the fireplace should stay cold until something is fixed.
The middle pages: photos and video stills
Each finding has its own photo with a caption written in house terms, not trade shorthand. A still from the camera run shows a tile joint with a gap. Beside it we say what the gap does: heat and smoke reach the brick around the liner, and over time the flue stops drawing well. The video file itself goes with the report.
This is where our draft work shows up. We light a small fire or use a smoke pencil and note where the smoke went. A fireplace that spills smoke when the kitchen hood runs gets a line about house air, which matters to a buyer planning to keep that hood.
- Firebox and damper, with the opening measured
- Smoke chamber and throat, photographed from below
- Flue liner, from the camera run, joint by joint
- Crown, cap and flashing, photographed from the roof
The last page: what to do about it
Every finding ends with a next step and, where we publish a price, the figure. A missing cap reads as a cap install, quoted after we measure. A wide crown or a copper cap changes the price. A flue that needs a liner reads as quoted in writing after the inspection, because liner jobs vary by height, size and access. Nothing on this page is a guess dressed up as a number.
Buyers use this page to ask for a repair or a credit. Sellers use it to decide whether to fix first. Either way, both sides read the same list. We serve Rosemead and the nearby San Gabriel Valley cities, and the report format is the same on every house.
What the sale inspection costs
A home sale calls for a Level 2 under NFPA 211. The price depends on the number of flues and roof access.
- Camera inspection of the full flue (Level 2)
- $395
- Recheck after repairs (Level 1)
- $55
Repairs found during the inspection are listed with our published price where one exists, and quoted in writing where it does not.
Questions buyers and sellers ask
Why does a sale need Level 2 rather than Level 1?
At a change of ownership NFPA 211 points to Level 2. A Level 1 only looks at what can be seen without tools. The Level 2 adds the camera run through the flue and a look at the attic and roof where the chimney passes through.
Who receives the report?
Whoever you name when you book. Most clients send it to themselves and their agent. Sellers sometimes send it to both agents. We do not send it to anyone you did not list.
Does the report say whether the fireplace smokes?
Yes. We run a draft test and write down where the smoke went, with the doors, windows and fans as we found them. If the fireplace only spills with an exhaust fan running, the report says so.
Will you quote the repairs?
Fixes with a published price are listed with it. Liners, rebuilds and other larger jobs are quoted in writing after the inspection, on a separate page the buyer and seller can both see.
Do I need to be at the house?
No. An agent or the seller can let us in. The report and photos reach you the same way whether or not you attend.
Get the report both sides can read
Use the Call button below, or send the form and we take the address and the report recipients on the callback.