A gas fireplace that leaves black film on the glass, smells sharp when it lights or shows lazy yellow flames is telling you something about its air and its burner.

Request This Visit

What the Visit Covers

Gas fireplaces gather dust, spider webs and lint in the burner and pilot, and logs drift out of place whenever the glass comes off. The flame turns yellow, soot builds on the glass and a faint exhaust smell reaches the sofa. We clean the burner ports, pilot hood and sensor, set the logs to the maker's layout, clean the glass, check the vent cap outside and take a carbon monoxide reading with the unit running.

Logs reset to the maker's layout
Burner ports and shutter cleared
Pilot hood and sensor brushed
Glass cleaned of sooty film
Outdoor vent cap checked for nests

"The Glass Turns Black and It Smells When It Starts"

A gas fireplace should burn with little soot and almost no smell after the first few minutes of a season. When the glass hazes over with white film, the cause is usually minerals from the gas and the burner's normal work, and cleaning takes care of it. When the glass turns black, that is soot, and soot means the flame is not getting the air it needs. Logs moved out of place during a past cleaning, a burner port clogged with dust or spider webs, or a vent partly blocked outside can all starve the flame. A sharp or burning smell at startup is often dust on the burner and logs cooking off, but it can also be a sign of exhaust escaping where it should not. We tell you which one it is after looking, not before, and the notes say what we found, with a photo of the burner and the glass as they were when we arrived.

The cleaning covers the parts that set the flame. We shut off the gas, remove the glass, take out the logs and embers, and clean the burner ports, the pilot assembly and the thermocouple or thermopile. The logs go back in the exact pattern the maker specifies, because a log sitting in the flame path is one of the most common causes of soot. We clean the glass with a cleaner made for the ceramic, look at the gasket for gaps, and reseal it. Outside, we check the vent termination for nests, plants or anything that can block the exhaust. Then we light it, look at the flame color and shape, and take a carbon monoxide reading in the room with the fireplace running for several minutes. If the flame is still lazy and yellow after all that, the cause is air or gas pressure, and we say so.

Vented, Direct-Vent and Vent-Free Units

Gas fireplaces come in three types, and each one is cleaned with its own risks in mind. A direct-vent unit has sealed glass and a two-layer pipe that draws combustion air from outside and sends exhaust back out, so the glass gasket and the termination cap matter most. A B-vent unit draws air from the room and sends exhaust up a pipe, so it can spill fumes into the room if the pipe is blocked or the house is short of air. A vent-free unit puts its exhaust into the room by design and relies on an oxygen depletion sensor to shut down if the air runs thin. On vent-free units, we clean and test that sensor first. For any type, a fireplace that keeps going out after a few minutes is often a sign of a dirty thermocouple or a venting issue, and the cleaning tells us which.

Most gas fireplaces in Rosemead and nearby cities like El Monte need a cleaning about once a year, usually before the cool months. Homes with pets, nearby construction or a lot of dust may need it more often. If the fireplace sits unused for a whole season, spiders can build in the pilot tube and the vent, which is a common reason for a pilot that will not stay lit come November. When the cleaning turns up a failed part, such as a worn thermocouple or a cracked glass panel, we tell you and quote the repair in writing. You receive a short note with photos of the burner, logs and vent cap, plus the CO reading, so you know the fireplace was safe to run when we left and what to watch for before next season.

  • Cause First
  • Plain Findings
  • Quote in Writing
  • Retest After